  • Bussmann BP/FRN-R-50ID Time Delay Fuse, 50 A, 250 V, 20, 200 kA Interrupt

    SKU: 7116452

    Brand: Bussmann

    5 items left


    Bussmann series Fusetron cartridge fuses are 23% more energy-efficient and offer the ideal time delay performance. Their dual-element feature allows closer sizing to load for excellent protection of motors and transformers. These Class RK5 fuses with a 200 kA interrupting rating can be used in a broad range of applications. When sized correctly, they help protect motors from burnout caused by overloads or single phasing. The time delay feature allows the initial startup current surge for typical motors to pass, but opens prior to motor burnout when longer, dangerous overloads are present. In addition, the dual-element design opens in as little as 0.004 secs if the fuse experiences short circuit conditions. All fuses are UL listed Class R (IR: 200 kA). Groove in end cap or notch in knife blade permit the fuse to be used in only Class H, Class K or Class R fuse blocks.

    Product Details

    Manufacturer: EATON

    Manufacturer's Part Number: BP/FRN-R-50ID

    Show me more Specialty Fuses

    • Simplifies and improves blackout prevention
    • Helps protect motors against burnout from overloads
    • Provides motor overload, ground fault and short circuit protection
    • Helps protect motors against burnout from 1-phase on 3-phase systems
    • The overload element provides protection against low level overcurrent of overloads
    • Offer consumers the additional advantage of blown fuse status that makes finding the open fuse easier and faster
    • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high-performance, short circuit and overload protection
    Current Rating 50 A
    Diameter 13/16 in
    Element Type Dual
    Indicator Type Indicating
    Interrupt Rating 20, 200 kA
    Length 3 in
    Terminal Type Ferrule
    Type Current Limiting
    Voltage Rating 250 V
    Catalog Click here to download
    Specification Sheet Click here to download